INDEX OF TERMS
L

[A] [B] [C] [D] [E] [F] [G] [H] [I] [J] [K] [L] [M]
[N] [O] [P] [Q] [R] [S] [T] [U] [V] [W] [X] [Y] [Z]

Terms are listed in alphabetical order, with reference to the number of the subchapter(s) where they can be found. Clicking on a term loads the appropriate section pdf file. If a term is not a separate entry, the entry at which it can be found is given in parentheses.  Terms marked with an asterisk ( *) are not recommended.

Label  16.2;   19.2.3
Labelling  16.2
 - conjugation  16.2
 - exchange  16.2
 - isotopic  16.2
 - non-isotopic  16.2
 - recoil  16.2
 - Wilzbach  16.2
Laboratory  18.7.2
 - micro-sample  10.3.4.9.3
 - -performance study  18.7.1
 - sample  10.3.4.9.1;   18.3.6
 - unit operation (LUO)  7.3
Lag  10.3.2.6
Lambert law  11.2
LAMES  17.3
Laminar air-flow cabinets  10.3.4.9.1
 - flame  10.3.4.2.2
 - sheath  10.3.1.2.7
LAMMA  17.3;   17.7.2
Lamp  10.3.1.5
Landolt reaction  15.2
 - reaction method  15.2
Language, high-level  7.2
Laporte rule  11.2
Lapse rate  19.3.1
 - rate temperature  19.3.1
Larmor angular frequency  1.3.4
Laser  10.3.1.6;   10.3.6.2.2;   11.2
 - action  10.3.1.6.1;   11.2
 - -active substance  10.3.1.6.2
 - argon ion  11.2
 - beam  10.3.1.6.1
 - cadmium-helium  11.2
 - chemical  11.2
 - CO2  11.2
 - copper vapour  11.2
 - diode  11.2
 - dye  10.3.1.6.6;   11.2
 - erosion  10.3.4.1.3
 - excimer  11.2
 - free electron  11.2
 - free-running  11.2
 - gas  10.3.1.6.6;   11.2
 - helium-cadmium  11.2
 - helium-neon  11.2
 - ionization  12.3.1
 - krypton ion  11.2
 - liquid  10.3.1.6.6
 - local analysis  10.3.4.7.2
 - micro emission spectroscopy  17.3
 - microprobe mass analysis  17.3;   17.7.2
 - mirrors  10.3.1.6.1
 - mode-locked  11.2
 - neodymium  11.2
 - nitrogen  11.2
 - output  10.3.1.6.6
 - - energy  10.3.1.6.1
 - - power  10.3.1.6.1
 - plume  10.3.1.6.7
 - pulse  10.3.1.6.1
 - Q-switched  11.2
 - Raman microanalysis  17.3
 - resonator  10.3.1.6.1
 - ruby  11.2
 - -shot  10.3.4.7.2
 - solid state  11.2
 - source  10.3.1.6
 - spikes  10.3.1.6.4
 - tunable  10.3.5.1.1
Lasing threshold  10.3.1.6.3
Latent image  11.2
Lateral diffusion interferences  10.3.4.3.4
Law of mass action  10.3.1.1.1
Layer (in network)  7.3
 - gradient  9.2.3.1
Leaching (see Extract  9.4.1; see Solvent extraction  9.4.1)
Lead sulfide photoconductive detectors  10.3.2.5
Leak valve  12.4.4
Leakage rate  12.4.4
LEED  17.3;   17.7.3
Length of column  9.2.3.2
Level (X-ray)  10.3.4.8.2
LIDAR  19.3.1
Lifetime  11.2
 - apparent  11.2
 - luminescence  10.3.6.3.5
 - radiative  11.2
Ligand  19.2.3
 - field splitting  11.2
Light polarization  11.2
 - scattering  11.2
 - -scattering immunoassay (see Nonradioisotopic immunoassay  19.2.3)
Limit of detection  8.3.2.1;   10.3.3.3.1;   18.4.3.7
Limiting adsorption current  8.4
 - catalytic current  8.4
 - current  8.4
 - diffusion current  8.4
 - forepressure  12.4.4
 - kinetic current  8.4
 - load  7.3
 - mean  18.4.3.5
 - migration current  8.4
 - stops  10.3.2.1.3
LIMS  7.2
Line, operating  9.4.4
 - profile function  10.2.1.1.3
 - shift  10.2.1.1.3
 - starting  9.2.3.3
 - -to-background radiant power ratio  10.3.2.1.8
Linear absorbance  10.3.5.2.2
 - absorption coefficient  10.3.2.1.3
 - attenuation coefficient  10.2.1.2.4
 - CCD  10.3.2.6
 - decadic absorption coefficient  10.3.5.2.2
 - dispersion  10.3.2.1.3
 - electro-optical effect  10.3.1.6.5
 - energy transfer  16.2
 - focused structure  10.3.2.3.6
 - photoelectric absorption coefficient  10.2.1.2.6
 - range  9.2.4.5
 - retention index (see Kováts Index  9.2.3.7)
 - scattering coefficient  10.2.1.2.6
 - sweep voltammetry  8.5.3
 - titration curve  6.2
Linearity, of responsivity  10.3.2.3.4
Linearly polarized radiation  10.3.6.2.5
Lines (of gratings)  10.3.2.1.3
Lineweaver-Burk plot  19.2.2
Linisher  10.3.4.9.2
Linked scan  12.3.3.2
Liquid, aspiration rate of  10.3.4.3.3
 - chromatography  9.2.1.4
 - consumption, rate of  10.3.4.3.3
 - distributing hand  7.3
 - front (see Mobile-phase front  9.2.3.8)
 - ion exchange  9.4.1
 - junction  3.4.12
 - lasers  10.3.1.6.6
 - -liquid distribution  9.4.1
 - -phase film thickness  9.2.3.2
 - - loading  9.2.3.1
 - sample injection  10.3.4.1.1
 - scintillation detector  16.2
Lithosphere  19.3.1
Littrow prism mounting  10.3.2.1.9
Live time  16.2
Load  4.2;   7.3;   9.4.4;   12.4.4
 - capacity  7.3
 - deflection  7.3
 - limiting  7.3
 - resistor  10.3.4.1.4
Loaded solvent  9.4.4 (see also Extract (noun)  9.4.2)
Loading (noun and verb)  9.4.4
Loading capacity  9.4.3
 - of liquid phase  9.2.3.1
Local analysis  10.3.4.7.2
 - (gas) temperature  10.3.1.1.1
 - area network (LAN)  7.2
 - thermal equilibrium  10.3.1.1.1;   10.3.1.3.8
Location absolute  7.3
 - relative  7.3
Logarithm of the retention factor  9.2.3.7
Logarithmic titration curve  6.2
Logit  16.2
Longitudinal mode (laser resonator)  10.3.1.6.1
Loop  7.3
Lorentzian band shape  11.2
Loss of solvent  9.4.4
Lot  10.3.4.9.1;   18.3.3
Low -current arc  10.3.1.2
 - energy electron diffraction  17.3;   17.7.3
 - pass filters  10.3.2.1.4
 - pressure arc lamps  10.3.1.5.5
 - - electrical discharge  10.3.1.5
 - - mercury lamp  11.2
 - - mercury-discharge lamps  10.3.5.1.1
 - - microwave induced plasma  10.3.1.4.8
 - temperature ashing  10.3.4.9.4
 - - cells  10.3.5.1.2
 - vacuum  12.4.4
LRMA  17.3
Luminescence  11.2;   16.2
 - corrected quantum yield of  10.3.6.3.6
 - delayed  11.2
 - energy yield of  10.3.6.3.6
 - (fluorescence phosphorescence) spectrometer  10.3.6.2
 - lifetime of  10.3.6.3.5
 - quantum efficiency of  10.3.6.3.6
 -  - yields  10.3.6.3.2
 - quenching  10.2.1.3.7
 - sensitized  10.2.1.3.7
Luminous efficiency  10.2.1
 - qualities  10.2.1
Lumiphore  11.2
Lyman ghosts  10.3.2.1.7
Lymph  19.2.1