INDEX OF TERMS
T

[A] [B] [C] [D] [E] [F] [G] [H] [I] [J] [K] [L] [M]
[N] [O] [P] [Q] [R] [S] [T] [U] [V] [W] [X] [Y] [Z]

Terms are listed in alphabetical order, with reference to the number of the subchapter(s) where they can be found. Clicking on a term loads the appropriate section pdf file. If a term is not a separate entry, the entry at which it can be found is given in parentheses.  Terms marked with an asterisk ( *) are not recommended.

Tactile sensor  7.3
Tailing  9.2.3.3
Tandem mass spectrometer  12.2
Tangent method 10.3.5.2.6;   (see Slope method  15.2)
Tank circuit  10.3.1.4.1
Tantalum carbide-coated tube  10.3.4.5.2
Tapered cavity  10.3.1.4.8
Tar  5.3
Target population  18.4.4
 - silicon  10.3.2.6
Task program  7.3
Tast interval  8.4
 - polarography  8.5.3
TCS  17.2.3
Teach (in robotics)  7.3
 - pendant  7.3
 - programming (in robotics)  7.3

Techniques, coupled simultaneous  5.2.3
 - discontinuous simultaneous  5.2.3
 - simultaneous  5.2.3

TEM  17.3;   17.7.3
Temperature, ambient  9.2.3.5
 - appearance 10.3.4.5.3
 - ashing  10.3.4.5.3
 - atomization  10.3.4.5.3
 - charring  10.3.4.5.3
 - cleaning  10.3.4.5.3

 - coefficient of resistance  10.3.2.3.5
 - - responsivity  10.3.2.3.4

 - column (see Separation temperature  9.2.3.5)
 - critical  9.2.7.1
 - detector  9.2.3.5
 - drying  10.3.4.5.3
 - effect  10.3.6.4.4
 - electron  10.3.1.1.1
 - electronic excitation  10.3.1.1.1

 - errors  10.3.5.2.9
 - excitation  10.3.1.1.1
 - final  5.2.2;   9.2.3.5
 - - isothermal  9.2.3.5

 - - pyrolysis  5.3
 - gas  10.3.1.1.110.3.4.5.3
 - initial  5.2.2;   9.2.3.5
 - injection  9.2.3.5

 - ionization  10.3.1.1.1
 - local  10.3.1.1.1

 - maximum pyrolysis  5.3
 - mid-analysis isothermal  9.2.3.5
 - noise  10.3.2.3.4
 - norm  10.3.1.1.1
 - profile  10.3.4.5.3
 - programme  10.3.4.5.3

 - -programmed pyrolysis  5.3
 - pyrolysis  10.3.4.5.3
 - reduced  9.2.7.1
 - retention  9.2.3.5
 - rise time (TRT)  5.3
 - rotational  10.3.1.1.1
 - separation  9.2.3.5
 - thermodynamic  10.3.1.1.1
 - time profile (TTP)  5.3
 - vaporization  10.3.4.5.3
 - vibrational  10.3.1.1.1
Temporal stabilization  10.3.1.2.3
Tenor*  9.4.4
Term (electronic state)  10.3.4.8.2
 - symbols for atomic states  1.3.5
 - - for molecular states  1.3.5

Terminal  7.3
Termolecular reaction (see Molecularity of a reaction  15.2)
Terrestrial global irradiance  (see AM (1) sunlight  11.2)
Tesla coil  10.3.1.4.2;   10.3.4.1.4;   10.3.1.3.4
Test electrode  8.4
 - material  18.7.2
 - portion  18.3.6
 - sample  10.3.4.9.1;   18.3.6;   18.7.2
 - - introduction of  7.3
 - solution  18.3.6
THEED  17.3
Theoretical end point  6.2
 - finesse  10.3.2.1.3
 - plate number (see Plate number  9.2.3.10)
 - resolution  10.3.2.1.6
 - resolving power  10.3.2.1.3
 - specific capacity  9.2.5.4
 - stage  9.4.4
Thermal analysis, differential  5.2.2
 - analysis, emanation  5.2.2

 - conductivity  1.3.12
 - - gauge  12.4.4
 - decomposition  10.3.4.9.5
 - desorption spectroscopy  17.3;   17.7.2
 - detector  10.3.2.3.3;   10.3.2.3.5
 - diffusivity  1.3.12
 - equilibrium  10.3.1.1.1
 - - local  10.3.1.1.1;
   10.3.1.3.8
 - evaporation  10.3.4.2.1
 - ionization  12.3.1
 - or Johnson noise  10.3.2.3.4
 - lensing  11.2
 - radiation  10.3.1.1.1
 - source  10.3.1.6
 - treatment  10.3.4.5.3
Thermally activated delayed fluorescence  11.2
 - ignited arc  10.3.1.2.2
 - insulated cells  10.3.5.1.2
Thermistor bolometer  10.3.2.3.5
 - gauge  12.4.4
Thermoacoustimetry  5.2.2
Thermobalance  5.2.2

Thermochemical analysis* (see Enthalpimetric analysis  5.4.1)
Thermochromism  11.2
Thermocouple  10.3.2.3.5
 - gauge  12.4.4
Thermodilatometry  5.2.2
Thermodynamic equilibrium  10.3.1.1.1
 - extraction constant (see Extraction constant at zero ionic strength  9.4.3)
 - temperature  10.3.1.1.1
Thermoelectric effect  10.3.2.3.5
Thermoelectrometry  5.2.2
Thermogram of pyrolysis  5.3
Thermogravimetry (TG)  5.2.2
Thermoluminescence  11.2(see also Thermooptometry  5.2.2)
Thermomagnetometry  5.2.2
Thermomechanical measurement  5.2.2

Thermometric* (see Enthalpimetric analysis  5.4.1)
 - chemical sensor  7.4
 - enthalpy titration* (see Thermometric titration  5.4.2)
 - titration  5.4.2
;   6.2
 - - curve  (see Thermometric titration  5.4.2)
 - - with catalytic endpoint detection (see Thermometric titration  5.4.2)

Thermomicroscopy (see Thermooptometry  5.2.2)
Thermooptometry  5.2.2
Thermoparticulate analysis  5.2.2
Thermophotometry (see Thermooptometry  5.2.2)

Thermopile  10.3.2.3.5
Thermorefractometry (see Thermooptometry  5.2.2)
Thermosonimetry  5.2.2

Thickness of liquid-phase film  9.2.3.2
 - of the reaction layer  8.4
Thinned CCD  10.3.2.6
Thixotropic agents  10.3.4.9.4
Three-electrode plasma  10.3.1.2.6
Three-slot burner  10.3.4.2.2
Throughput  12.4.4
 - rate*  7.4
Thyristor control  10.3.4.1.4
TICT state  11.2
Time, of atomization  10.3.4.5.3
 - breakdown  10.3.1.3.3
 - centrifugation  9.7
 - charring  10.3.4.5.3
 - cleaning  10.3.4.5.3

 - constant  10.3.1.4.4;   10.3.2.3.4
 - -correlated single photon counting   11.2
 - drying  10.3.4.5.3
 - of fall  10.3.2.3.4
 - gas hold-up  9.2.3.7
 - gas hold-up, corrected  9.2.3.7
 - hold-up  9.2.3.7

 - integrating  10.3.2.6
 - - photodiode arrays  10.3.2.6

 - -of-flight mass spectrometer  12.2
 - profile of temperature  5.3
 - pyrolysis  10.3.4.5.3
 - residence  7.4
 - -resolved measurements  10.3.2.3.3
 - - spectroscopy  10.3.1.3.8;   11.2
 - sampling  8.4
 - shut-down  7.4
 - start-up  7.4

 - of temperature rise  5.3
 - total heating  5.3

 - transition  8.4
 - out  7.3
Timed injector  9.2.7.3
Tissue-blender  10.3.4.9.3
Titer  6.2
Titrant  6.2
Titration  6.2
 - acid-base  6.2
 - acidimetric  6.2
 - alkalimetric  6.2
 - amperometric  6.2
;   8.5.2
 - calorimetric  5.4.2
 - chelatometric  6.2
 - chronopotentiometric  6.2

 - conductometric  6.2;   8.5.4
 - - high-frequency  8.5.4

 - coulometric  6.2;   8.5.1
 - curve  6.2
 - - enthalpymetric  (see Thermometric titration  5.4.2)
 - - linear  6.2
 - - logarithmic  6.2

 - - thermometric  (see Thermometric titration  5.4.2)
 - dielectrometric  8.5.4
 - differential potentiometric  8.5.1
 - error  6.2
 - fluorometric  6.2
 - high frequency  6.2
 - iodimetric  6.2
 - nephelometric  6.2
 - oxidation-reduction  6.2

 - polarographic* (see Amperometric titration  8.5.2)
 - polarometric* (see Amperometric titration  8.5.2)

 - potentiometric  6.2;   8.5.1
 - - controlled-current  8.5.1
 - - null-current* (see Differential potentiometry  8.5.1)
 - - zero-current* (see Differential potentiometry  8.5.1)

 - precipitation  6.2
 - radiometric  6.2
 - spectrophotometric  6.2

 - thermometric  5.4.2;   6.2
 - turbidimetric  6.2

Titre  19.2.3
Titrimetry  6.2
Tolerance  7.3
Top-down design  7.3

Torr  1.612.4.4
Total angle of deviation  10.3.2.1.3
 - consumption time  10.3.4.2.2
 - current spectroscopy  17.2.3
 - decomposition  10.3.4.9.5
 - heating time (THT)  5.3
 - ion current  12.4.2
 - mobile-phase time  9.2.6.2
 - - volume  9.2.6.2

 - - volume in column  9.2.6.1
 - retention time  9.2.3.7
 - - volume  9.2.3.7

 - transmittance  10.2.1.3.4
Totally porous packing  9.2.3.1
Townsend first coefficient  10.3.1.5.2
TPD  17.3;   17.7.2
Traceability  18.8.2; (see also Definitive method  18.4.2)
 - chain (see Traceability  18.8.2)
Traceable (see Traceability  18.8.2)

Tracer  16.2
 - generally labelled  16.2
 - isotopic  16.2
 - nominally labelled  16.2
 - specifically labelled  16.2
 - stereospecifically labelled  16.2
 - uniformly labelled  16.2
Track detector nuclear  16.2
 - nuclear  16.2

Trajectory  7.3
 - control  7.3

Transducer  7.2
 - part of a sensor  7.4
Transfer  7.3
 - activity coefficient  9.4.3
 - coefficient  (electrochemical)  1.3.10
Transferred plasma  10.3.1.2.6
Transient pressure gradient  10.3.2.3.5
 - spectroscopy  11.2
Transistor field effect  8.3.2.410.3.2.5
 - ion-selective field effect  8.3.2.4
Transit time  10.3.2.3.4;   10.3.1.4.2
Transition, charge-transfer  11.2
 - (dipole) moment  11.2

 - flow  12.4.4
 - free-bound  10.2.1.1.2
 - free-free  10.2.1.1.2

 - frequency  1.3.5
 - interchromophoric, radiationless  10.2.1.3.7
 - intermolecular, radiationless  10.2.1.3.7

 - interval  6.2
 - intrachromophoric, radiationless  10.2.1.3.7
 - point  6.4.2
 - polarization  11.2
 - potential  6.4.3
 - probability for absorption  10.3.1.1.4
 - - spontaneous emission  10.3.1.1.4
 - - stimulated emission  10.3.1.1.4

 - radiationless 10.3.4.8.2;   10.2.1.3.6;   11.2
 - radiative  10.2.1.3.6
 - of rotational energy  10.2.1.3.1
 - Rydberg  11.2
 - simultaneous pair  11.2

 - state  15.2
 - time  8.4
 - vertical  11.2
 - of vibrational energy  10.2.1.3.1
 - vibronic  10.2.1.3.3;
   11.2
 - wave number  1.3.5
Transitive, radiative  11.2
Transmission  12.2
 - electron microscopy  17.3;   17.7.3
 - high energy electron diffraction  17.3
 - reflection factor  10.3.2.1.3
Transmittance  1.3.6;   11.2
 - internal  10.2.1.3.4
 - total  10.2.1.3.4

Transport 7.3
 - discrete  7.3

 - interferences  10.3.4.3.4
 - number  1.3.10
 - solute volatilization interference  10.3.4.3.4
Transversal mode  10.3.1.6.1
Transverse electromagnetic mode  10.3.1.4.8
Trap  12.4.4
Treated solution  18.3.6
Trennzahl (see Separation number  9.2.3.10)
Triangular wave voltammetry  8.5.3
Triboluminescence  11.2
Triggerable stationary gap  10.3.1.3.3
Triode getter pump  12.4.4
 - pump  12.4.4

Triplet state  11.2
 - - triplet absorption  10.2.1.3.6
 - - annihilation  11.2
 - - energy transfer  11.2
Trivial energy transfer  11.2

True value  2.2;   10.3.3.1.7;   18.2.1;   18.4.3.5
Trueness 18.6.1
Tube glassy carbon  10.3.4.5.2
 - - in-tube atomizer  10.3.4.5.2

Tunable lasers  10.3.5.1.1
Tuned amplifier measuring system  10.3.1.5.8
 - - line oscillator  10.3.1.4.1
Tungsten-halogen lamp  10.3.1.6.3;   10.3.5.1.1;   11.2
 -probe atomizer  10.3.4.5.2
 -strip  10.3.4.5.2

Tuning stub  10.3.1.4.8
Tunnelling  11.2  (see also STM  17.7.3)
Turbidimetric titration  6.2
Turbidity  11.2
Turbomolecular pump  12.4.4
Turbulent flame  10.3.4.2.2
Twin nebulizer  10.3.4.2.2

Two-colour indicator  6.2;   6.4.2
Two-dimensional array CCD  10.3.2.6
 - chromatography  9.2.1.6
Two-photon excitation  11.2
 - process 11.2

Two-point measurement mode (in enzymology)  19.2.2
Two-step procedure  10.3.4.7.1
Twyman interferometer  10.3.2.1.4