Pure Appl. Chem. 76(4), 815-828, 2004

Pure and Applied Chemistry

Vol. 76, Issue 4

Selective control and rate enhancement of reactions involving catalytic reduction of organohalides and reduced form of myoglobulin in microemulsions

G. N. Kamau and B. Munge

Department of Chemistry, Box U-60, University of Connecticut, Storrs,
CT 06269-3060, USA; Department of Chemistry, University of Nairobi,
P.O. Box 30197, Nairobi, Kenya

Abstract: Myoglobin (horse heart, Mb) adsorbed on carbon electrodes or in solution at platinum electrodes was used for electrocatalytic reduction of trans-1,2-dibromocyclohexane
(DBCH) and trichloroacetic acid (TCA) in a bicontinuous microemulsion, prepared from sodium didodecyl sulfate (SDS) or hexadecyltrimethylammonium bromide (CTAB), tetradecane, pentanol, and water. Carbon electrodes (glassy carbon, GC, and pyrolytic graphite, PG) exhibited adsorption peaks, whereas platinum (Pt) portrayed diffusion-controlled peaks. Electrode reduction of Mb had E0' at –0.179 ± 0.013 V at GC/SDS, –0.189 ± 0.015 at
GC/CTAB, and –0.562 ± 0.018 at Pt/SDS and 0.611 ± 0.008 at Pt/CTAB media.Current efficiencies for electrocatalytic reduction of TCA were higher than that for reduction of dibromocyclohexane. For both substrates, dibromocyclohexane and trichhloroacetic acid, a
lowering of overpotential of at least 1.3 V was achieved. Overall, the Pt electrode exhibited higher catalytic efficiencies compared to carbon electrodes, suggesting higher surface concentration and unhindered orientation of the substrate on the Pt electrode. For DBCH, catalytic efficiencies decreased with scan rate, at carbon electrodes as expected for homogeneous solutions, whereas an average value of 2.22 ± 0.42 in SDS and 3.29 ± 0.76 in CTAB
microemulsion was obtained at Pt electrodes at a scan rate range of 15 to 3000 mVs–1. Pseudo-first-order rate constants (k') for the rate-determining step (rds) involving reaction of organohalides with catalyst had an average value of 41 ±1 M–1 s–1 for reduction of
DBCH/SDS and 4.8 ± 1.0 ×102 M–1 s–1 for reduction of TCA/SDS. Moreover, rate constants were higher in CTAB microemulsion, giving values of 1.5 ±0.016 ×102 and 2.75 ±0.67 ×
103 M–1 s–1 for DBCH and TCA, respectively. Positive interfacial charge of the microemulsion conduits influenced catalytic reaction of catalyst and the substrate. Under the conditions of the experiment, no hydrogen evolution was observed at Pt electrodes.

*Plenary lectures presented at the Inaugural Conference for the Southern and Eastern Africa Network of Analytical Chemists (SEANAC), Gaborone, Botswana, 7-10 July 2003. Other presentations are published in this issue, pp. 697-888.


Page last modified 11 June 2004.
Copyright © 2004 International Union of Pure and Applied Chemistry.
Questions or comments about IUPAC, please contact, the Secretariat.